Comparison of the Effect of Voluven and Ringer Solution in Cardiopulmonary Bypass on the Bleeding After the Surgery and Renal Function in Coronary Artery Bypass Graft Surgeries
Mansoor Jannati , Elahe Allahyari , Alireza Sadeghi Gilvayee
Cardiovascular Surgery Subspecialty, Anesthesiology Research Center and ICU, Shiraz University of Medical Sciences, Shiraz, Iran , janatim@sums.ac.ir
Abstract:   (3049 Views)
Background: This study compared the effect of Voluven and Ringer solution in cardiopulmonary bypass on the bleeding after the surgery and renal function in coronary artery bypass graft surgeries.
Methods: Two types of prime solution including ringer - as Crystalloid- and Voluven were used in two groups and compared in terms of bleeding and renal function during the first 24 hours after the surgery in intensive care unit (ICU) cardiac surgery.
Results: Amount of a 24-hour drainage was not statistically different (P > 0.05). There was not any significant difference between groups regarding urinary output in two time periods, pump time and during the first 24 hours after the patient’s entry to ICU. The mean of partial thromboplastin time postop in experiment and control groups was significantly different (P > 0.05). Plasma level of Bun-Cr  , sodium, Potassium, hemoglobin, hematocrit, BT, PT and INR Platelets was not significantly different during the first 24 hours after the surgery (P > 0.05). There was a significant difference between the two groups in terms of a need for blood transfusion   during the surgery and first 24 hours after the surgery (Ringer 1.70 ± 0.9, Vovuven 1.07 ± 1.1) (P = 0.019). There was not a significant difference between two groups in terms of urinary protein secretion during the first 24 hours after the surgery (P = 0.08).
Conclusions: It can be concluded that using Voluven as prime solution in comparison to lactate, in our study  did not cause any significant difference in bleeding after the surgery and there was not so much need for blood injection in these patients 
 
Keywords: Voluven, Prime solution of cardiopulmonary pump, The level of bleeding, Renal function, Cardiopulmonary pump
Full-Text [PDF 272 kb]   (1561 Downloads)    
Type of Study: Research | Subject: Special
Received: 2019/12/17 | Accepted: 2019/12/17 | Published: 2019/12/17
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Jannati M, Allahyari E, Sadeghi Gilvayee A. Comparison of the Effect of Voluven and Ringer Solution in Cardiopulmonary Bypass on the Bleeding After the Surgery and Renal Function in Coronary Artery Bypass Graft Surgeries. aumj 2019; 8 (4) :355-364
URL: http://aums.abzums.ac.ir/article-1-1012-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 8, Issue 4 (vol.8, No. 4, 2019 2019) Back to browse issues page
نشریه دانشگاه علوم پزشکی البرز Alborz University Medical Journal
Persian site map - English site map - Created in 0.05 seconds with 39 queries by YEKTAWEB 4645