[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Indexing::
open access policy::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Registered in

AWT IMAGE

AWT IMAGE

..
:: Volume 1, Issue 3 (6-2012) ::
aumj 2012, 1(3): 123-129 Back to browse issues page
Accuracy of Inferior Vena Cava Ultrasonography in Determining Central Venous Pressure
H. Derakhshanfar1 , A. Zolfaghari Sadrabad * 2, A. Amini1 , H. Hatam-Abadi1 , R. Farahman-Rad1
1- Emergency Medicine, Shahid Beheshti University of Medical Science, Tehran, Iran
2- Emergency Medicine, Shahid Beheshti University of Medical Science, Tehran, Iran , akramzolfaghari@gmail.com
Abstract:   (10957 Views)
Introduction: Clinical ultrasonography may be provides a quick and non-invasive Modality for evaluation of patients’ hemodynamics for volume status. In this study we want to assess and attempt to analyze accuracy of inferior vena cava (IVC) ultrasonography and central venous catheterization in determine central venous pressure (CVP). Method and Materials: The patients were undergoing central venous catheterization, have been kept in an observational, diagnostic and comparative study. IVC diameters were determined by 2- dimensional bedside ultrasonography during 1 respiratory cycle and the caval index was measured. The correlation of CVP and caval index was measured. In addition, the sensitivity, specificity, positive and negative predictive values of caval index was calculated. Results: All 114 patients were divided in three groups: 59% of patients had CVP<8, 19% had 8 ≥ CVP≤12 and 22% had CVP>12. The relationship between caval index and CVP was 0.75. The results of this study demonstrated that the caval index≥ 50% can predict the CVP<8 with 91%sensitivity, 94% specificity, 94%positive predictive value, and 89.5% negative predictive value. Also, the caval index ≤28% can predict a CVP>12 with 96% sensitivity, 94.5%specificity, 83% positive predictive value and 98.8% negative predictive value. Discussion: Our results in this study told us that there is significant correlation between caval index≥50% and CVP<8 or caval index 28% and CVP>12. Conclusion: Ultrasound assessment of IVC dimensions may provide a quick and non-invasive hemodynamic monitoring method of assessing volume status and can performed by educated technician or medical students.
Keywords: Central Venous Pressure, hemodynamics, inferior vena cava, ultrasonography
Full-Text [PDF 311 kb]   (2757 Downloads)    
Type of Study: Research | Subject: General
Received: 2012/12/07 | Accepted: 2018/11/12 | Published: 2018/11/12
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Derakhshanfar H, Zolfaghari Sadrabad A, Amini A, Hatam-Abadi H, Farahman-Rad R. Accuracy of Inferior Vena Cava Ultrasonography in Determining Central Venous Pressure. aumj 2012; 1 (3) :123-129
URL: http://aums.abzums.ac.ir/article-1-45-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 1, Issue 3 (6-2012) Back to browse issues page
نشریه دانشگاه علوم پزشکی البرز Alborz University Medical Journal
Persian site map - English site map - Created in 0.05 seconds with 39 queries by YEKTAWEB 4660