<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Alborz University Medical Journal</title>
<title_fa>نشریه علمی پژوهشی دانشگاه علوم پزشکی  البرز</title_fa>
<short_title>aumj</short_title>
<subject>Medical Sciences</subject>
<web_url>http://aums.abzums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-3839</journal_id_issn>
<journal_id_issn_online>2588-3046</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61186/aums</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1394</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2015</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<volume>4</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی و مقایسه کارایی منعقد کننده پلی‌فریک سولفات (PFS) درمقایسه با پلی آلومینیوم کلراید (PAC) در حذف کدورت و کلیفرم در تصفیه آب اهواز</title_fa>
	<title>Investigation Of Efficiency Of Polyferric Sulfate(PFS) Coagulant Compared To Poly Aluminium Choloride (PAC) in Ahvaz Water Treatment</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot; style=&quot;margin-right: 116.25pt;&quot;&gt;&lt;strong&gt;زمینه&lt;/strong&gt; &lt;strong&gt;و&lt;/strong&gt; &lt;strong&gt;هدف&lt;/strong&gt;&lt;span dir=&quot;LTR&quot;&gt;:&lt;/span&gt;فرایند انعقاد و لخته سازی در تصفیه آب از جایگاه ویژه ای برخوردار است. در حال حاضر از ماده منعقدکننده پلی&#8204;آلومینیوم کلراید در تصفیه خانه آب کیان آباد استفاده می گردد. هدف از این پژوهش بررسی و مقایسه کارایی منعقد کننده پلی فریک سولفات(&lt;span dir=&quot;LTR&quot;&gt;PFS&lt;/span&gt;) درمقایسه با پلی آلومینیوم کلراید(&lt;span dir=&quot;LTR&quot;&gt;PAC&lt;/span&gt;) درحذف کدورت و کلیفرم در تصفیه آب اهواز می&#8204;باشد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;margin-right: 116.25pt;&quot;&gt;&lt;strong&gt;روش&lt;/strong&gt; &lt;strong&gt;کار&lt;/strong&gt;&lt;span dir=&quot;LTR&quot;&gt;:&lt;/span&gt; این تحقیق در مقیاس آزمایشگاهی و با استفاده از دستگاه جارتست در تصفیه خانه آب اهواز انجام شد.آزمایشات در محدوده کدورت &lt;span dir=&quot;LTR&quot;&gt;NTU&lt;/span&gt; 35&amp;nbsp; در تصفیه خانه آب اهواز انجام گرفت.پارامترهای مورد بررسی شامل غلظت ماده منعقدکننده ،&lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt;، کدورت، کلیفرم کل، کلیفرم مدفوعی و باکتری&#8204;های هتروتروف می باشد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;margin-right: 116.25pt;&quot;&gt;&lt;strong&gt;یافته&lt;/strong&gt;&lt;strong&gt;&#8204;&lt;/strong&gt;&lt;strong&gt;ها&lt;/strong&gt;&lt;span dir=&quot;LTR&quot;&gt;:&lt;/span&gt; بهینه ترین شرایط کارایی پلی آلومینیوم کلراید 8&lt;span dir=&quot;LTR&quot;&gt;PH=&lt;/span&gt; ،سرعت اختلاط سریع معادل &lt;span dir=&quot;LTR&quot;&gt;rpm&lt;/span&gt; 120 و دوز بهینه &lt;span dir=&quot;LTR&quot;&gt;ppm&lt;/span&gt;5 می&#8204;باشدکه در 8&lt;span dir=&quot;LTR&quot;&gt;PH=&lt;/span&gt; راندمان حدف کدورت برابر با 14/93 و در دوز&amp;nbsp; بهینه &lt;span dir=&quot;LTR&quot;&gt;ppm&lt;/span&gt; 5&amp;nbsp; راندمان حذف کدورت برابر با 80/93 درصد می&#8204;باشد. بهینه ترین شرایط کارایی پلی فریک سولفات8&lt;span dir=&quot;LTR&quot;&gt;PH=&lt;/span&gt;، سرعت اختلاط سریع معادل &lt;span dir=&quot;LTR&quot;&gt;rpm&lt;/span&gt;120 و دوز بهینه &lt;span dir=&quot;LTR&quot;&gt;ppm&lt;/span&gt;8 می&#8204;باشد که در 8&lt;span dir=&quot;LTR&quot;&gt;PH=&lt;/span&gt; راندمان حدف کدورت برابر با 86&lt;span dir=&quot;LTR&quot;&gt;/&lt;/span&gt; 94و در دوز&amp;nbsp; بهینه &lt;span dir=&quot;LTR&quot;&gt;ppm&lt;/span&gt;8 راندمان حذف کدورت برابر با 86/94 درصد می&#8204;باشد. درشرایط بهینه عملکرد منعقد کننده پلی آلومینیوم کلراید در دوز &lt;span dir=&quot;LTR&quot;&gt;ppm&lt;/span&gt; &amp;nbsp;5راندمان حذف باکتری&#8204;های کلیفرم کل ،کلیفرم مدفوعی و باکتریهای هتروتروفیک، به ترتیب برابر است با 12/90%،70/83%، 08/84%. درشرایط بهینه عملکرد منعقد کننده پلی فریک سولفات در دوز &lt;span dir=&quot;LTR&quot;&gt;ppm&lt;/span&gt; &amp;nbsp;8 راندمان حذف باکتریهای کلیفرم کل ،کلیفرم مدفوعی و باکتری&#8204;های هتروتروفیک به ترتیب برابر است با 48/90%،83/84% و 69/84%.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;margin-right: 116.25pt;&quot;&gt;&lt;strong&gt;نتیجه&lt;/strong&gt;&lt;strong&gt;&#8204;&lt;/strong&gt;&lt;strong&gt;گیری&lt;/strong&gt;&lt;span dir=&quot;LTR&quot;&gt;:&lt;/span&gt; در پایان بین دو گروه &lt;span dir=&quot;LTR&quot;&gt;PFS&lt;/span&gt; و &lt;span dir=&quot;LTR&quot;&gt;PAC&lt;/span&gt; از نظر راندمان حذف کدورت تفاوت جزئی وجود دارد که این تفاوت از نظر آماری معنی&#8204;دار نیست.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p style=&quot;margin-left: 116.25pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;Background:&lt;/em&gt;&lt;/strong&gt; Coagulation process has a important place in water treatment&lt;span dir=&quot;RTL&quot;&gt;.&lt;/span&gt; Currently, poly aluminum chloride is used in Kian-abad water treatment plant. The purpose of this study is to compare and investigate the efficiency of coagulants of poly ferric sulfate(PFS) against poly aluminum chloride (PAL) in removing turbidity and coliform bacteria in Ahwaz water treatment plant.&lt;/p&gt;

&lt;p style=&quot;margin-left: 116.25pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;Methods:&lt;/em&gt;&lt;/strong&gt; This study, was performed in lab scale and using of jartest apparatus in Ahwaz water treatment. Experiments was conducted in 35NTU turbidity in Ahwaz water treatment plant. The studied parameters included concentrations of coagulants, pH, turbidity, total coliform, fecal coliform and heterotrophic bacteria.&lt;/p&gt;

&lt;p style=&quot;margin-left: 116.25pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;Results:&lt;/em&gt;&lt;/strong&gt; The most optimal efficiency conditions of poly aluminum chloride were pH=8, rapid mixing of 120rpm and optimal dose of 5ppm which was 93.14% in pH=8 and 93.80% for optimal dose of 5ppm. The most optimal condition for poly ferric sulfate included pH=8, rapid mixing of 120 rpm and optimal dose of 8ppm.&lt;/p&gt;

&lt;p style=&quot;margin-left: 116.25pt;&quot;&gt;In optimal condition of performance for poly aluminum chloride, efficiency of removing total coliform, fecal coliform and heterotrophic bacteria were 90.12, 83.70, 84.08% respectively. In optimal condition of poly ferric sulfate in dose of 8ppm efficiency removing total coliform, fecal coliform, and heterotrophic bacteria were 90.48, 84.83, and 84.69.&lt;/p&gt;

&lt;p style=&quot;margin-left: 116.25pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;Conclusion:&lt;/em&gt;&lt;/strong&gt; Finally, there was small difference between both PFS and PAC group about turbidity removal efficiency that was not significant statistically.&lt;/p&gt;
</abstract>
	<keyword_fa>انعقاد, کدورت, پلی آلومینیوم کلراید, پلی‌فریک سولفات</keyword_fa>
	<keyword>Coagulation, Polyaluminum Chloride, Polyferric sulfate, Turbidity</keyword>
	<start_page>266</start_page>
	<end_page>277</end_page>
	<web_url>http://aums.abzums.ac.ir/browse.php?a_code=A-10-1-127&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>A.</first_name>
	<middle_name></middle_name>
	<last_name>Takdstan</last_name>
	<suffix></suffix>
	<first_name_fa>افشین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>تکدستان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846002654</code>
	<orcid>10031947532846002654</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associat Professor, Environmental Health Engineering and Environmental Technologies Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran</affiliation>
	<affiliation_fa>دانشیار، گروه مهندسی بهداشت محیط و عضو مرکز تحقیقات فناوریهای زیست محیطی دانشگاه علوم پزشکی جندی شاپور اهواز، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Sh.</first_name>
	<middle_name></middle_name>
	<last_name>Shirzadi</last_name>
	<suffix></suffix>
	<first_name_fa>شراره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شیرزادی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846002655</code>
	<orcid>10031947532846002655</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>کارشناس ارشد مهندسی محیط زیست، دانشگاه آزاد اسلامی واحد علوم و تحقیقات خوزستان</affiliation_fa>
	 </author>


	<author>
	<first_name>N.</first_name>
	<middle_name></middle_name>
	<last_name>Orooji</last_name>
	<suffix></suffix>
	<first_name_fa>نغمه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عروجی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>n.oroji2007@gmail.com</email>
	<code>10031947532846002656</code>
	<orcid>10031947532846002656</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>M.Sc Thesis of  Applied Chemistry, Ahwaz Water and Wastewater Company. Khouzestan, Iran</affiliation>
	<affiliation_fa>کارشناسی ارشد شیمی کاربردی، شرکت آب و فاضلاب اهواز – ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Noori sepehr</last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نوری‌سپهر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846002657</code>
	<orcid>10031947532846002657</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor of Environmental Health Engineering ,Alborz University of Medical Sciences ,Karaj, Iran</affiliation>
	<affiliation_fa>دانشیار، گروه مهندسی بهداشت محیط، دانشگاه علوم پزشکی البرز،کرج ،ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>R.</first_name>
	<middle_name></middle_name>
	<last_name>Jalilzadeh</last_name>
	<suffix></suffix>
	<first_name_fa>رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جلیل‌زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846002658</code>
	<orcid>10031947532846002658</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Civil Engineering, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran</affiliation>
	<affiliation_fa>استادیار، گروه مهندسی محیط زیست، دانشگاه آزاد اسلامی واحد اهواز، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
