[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Indexing::
open access policy::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Registered in

AWT IMAGE

AWT IMAGE

..
:: Volume 5, Issue 1 (2-2016) ::
aumj 2016, 5(1): 40-44 Back to browse issues page
Comparison of the Laryngeal View with Airtraq and Macintosh Laryngoscopes During Tracheal Intubation
S. Beiranvand , N. Eslamizade
Department of Anesthesiology, Shohadaye Ashayer Hospital, Lorestan University of Medical Sciences, Khorramabad, Iran
Abstract:   (4013 Views)

Purpose: The aim of this study is to compare the laryngeal view in Airtraq and Macintosh laryngoscopes.

Methods: This descriptive observational study was conducted on hospitalized patients at Shohadaye Ashayer Hospital who were candidate for elective surgery with general anesthesia. One anesthesiologist evaluated and recorded glottis view with Macintosh laryngoscopy based on cormack lehane score and another anesthesiologist who was unaware of the observations of the previous anesthesiologist evaluated and recorded glottis view with Airtraq laryngoscope.

Results: The mean age of patients was 30.6 ± 8.89 years old. Mean BMI 22.10 ± 3.25 kg/m2 and duration of intubation was 28.3±6.92 seconds. The Airtraq laryngoscope significantly decreased the Cormack-Lehane score (P = 0.043). Cormack lehane score With the Macintosh laryngoscope was I in 187 patients (69%), II in 56 patients (21.3%), III in 20 patients (7.8%) and IV in 5 patients (1.9%) and with laryngoscope Airtraq was I in 248 cases (93.6%), II in 16 patients (5.2%) and III in 3 patients (1.1%). Improvement in view of larynx was observed in 194 cases (73.0%) with Airtraq laryngoscope and lack of improvement was seen in 73 (27.0%) cases.

Conclusion: Considering the high rate of improvement in observation of view of larynx with an Airtraq laryngoscope, decreasing the Cormack-Lehane score, and facilitating the tracheal intubation, Airtraq laryngoscope is a safe and useful for tracheal intubation in elective surgery with general anesthesia. 

Keywords: Airtraq, Macintosh, Laryngoscope, View, Larynx
Full-Text [PDF 118 kb]   (1791 Downloads)    
Type of Study: Research | Subject: Special
Received: 2016/05/03 | Accepted: 2016/05/03 | Published: 2016/05/03
Add your comments about this article
Your username or Email:

CAPTCHA



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Beiranvand S, Eslamizade N. Comparison of the Laryngeal View with Airtraq and Macintosh Laryngoscopes During Tracheal Intubation. aumj 2016; 5 (1) :40-44
URL: http://aums.abzums.ac.ir/article-1-408-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 5, Issue 1 (2-2016) Back to browse issues page
نشریه دانشگاه علوم پزشکی البرز Alborz University Medical Journal
Persian site map - English site map - Created in 0.07 seconds with 39 queries by YEKTAWEB 4645