:: Volume 4, Issue 4 (11-2015) ::
aumj 2015, 4(4): 266-277 Back to browse issues page
Investigation Of Efficiency Of Polyferric Sulfate(PFS) Coagulant Compared To Poly Aluminium Choloride (PAC) in Ahvaz Water Treatment
A. Takdstan1 , Sh. Shirzadi , N. Orooji * 2, M. Noori sepehr3 , R. Jalilzadeh4
1- Associat Professor, Environmental Health Engineering and Environmental Technologies Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
2- M.Sc Thesis of Applied Chemistry, Ahwaz Water and Wastewater Company. Khouzestan, Iran , n.oroji2007@gmail.com
3- Associate Professor of Environmental Health Engineering ,Alborz University of Medical Sciences ,Karaj, Iran
4- Department of Civil Engineering, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran
Abstract:   (5541 Views)

Background: Coagulation process has a important place in water treatment. Currently, poly aluminum chloride is used in Kian-abad water treatment plant. The purpose of this study is to compare and investigate the efficiency of coagulants of poly ferric sulfate(PFS) against poly aluminum chloride (PAL) in removing turbidity and coliform bacteria in Ahwaz water treatment plant.

Methods: This study, was performed in lab scale and using of jartest apparatus in Ahwaz water treatment. Experiments was conducted in 35NTU turbidity in Ahwaz water treatment plant. The studied parameters included concentrations of coagulants, pH, turbidity, total coliform, fecal coliform and heterotrophic bacteria.

Results: The most optimal efficiency conditions of poly aluminum chloride were pH=8, rapid mixing of 120rpm and optimal dose of 5ppm which was 93.14% in pH=8 and 93.80% for optimal dose of 5ppm. The most optimal condition for poly ferric sulfate included pH=8, rapid mixing of 120 rpm and optimal dose of 8ppm.

In optimal condition of performance for poly aluminum chloride, efficiency of removing total coliform, fecal coliform and heterotrophic bacteria were 90.12, 83.70, 84.08% respectively. In optimal condition of poly ferric sulfate in dose of 8ppm efficiency removing total coliform, fecal coliform, and heterotrophic bacteria were 90.48, 84.83, and 84.69.

Conclusion: Finally, there was small difference between both PFS and PAC group about turbidity removal efficiency that was not significant statistically.

Keywords: Coagulation, Polyaluminum Chloride, Polyferric sulfate, Turbidity
Full-Text [PDF 1172 kb]   (6480 Downloads)    
Type of Study: Research | Subject: Special
Received: 2016/02/07 | Accepted: 2016/02/07 | Published: 2016/02/07
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Takdstan A, Shirzadi S, Orooji N, Noori sepehr M, Jalilzadeh R. Investigation Of Efficiency Of Polyferric Sulfate(PFS) Coagulant Compared To Poly Aluminium Choloride (PAC) in Ahvaz Water Treatment. aumj 2015; 4 (4) :266-277
URL: http://aums.abzums.ac.ir/article-1-382-en.html